SL610 INFRARED SENSOR LAMP
INSTRUCTION
GENERAL:
This product is an energy-saving lamp, which can turn on when one comes and turn off when leaves. It can identify day and night automatically. It adopts infrared energy discharging detector, IC and SMD technology; it has stable performance. When one enters the detection field and trigger it, the infrared sensor will work and make the lamp on. When leaves, the lamp will die out automatically.
FUNCTION:
- It can identify day and night automatically, the ambient light of starting operation can be adjusted freely, it can work at night and stop in the daytime, it can be adjusted by users;
- Adjustable detection distance: It can be adjusted according to using location;
- Adjustable time-delay: It can be adjusted according to the local place;
- Time-delay is added continually, if one moves in detection field when the lamp is on, the light time will compute once more on the basis of the last induction¡¯s rest and delay the light time automatically.
SPECIFICATION:
Detection distance(<24¡æ): 2~11m
Detection range:180¡ã
140¡ã
Power sources: 180~240V/AC
100~130V/AC
Power frequency: 50~60Hz
|
Ambient-light:<10LUX~2000Lux
Delay-time: 5s~7min¡À2min
Rated Load:60W(max)
Installation height: 1.8m~2.5m
Working temperature:-20¡æ~+40¡æ
Working humidity: <93£¥RH
|
INSTALLATION:
Connect the power source into the lamp according to connection-wire diagram when you install it (connect brown and blue with power, red and blue with load)
- Select the specific installation position according to the following diagram
- The detection angle (top view)
- The strong detection field (arrow means one¡¯s moving direction)
- Poor detection field
- Detection distance and range (side view)
 |
 |
¢ó¡¡¡¡¡¡¡¡¡¡¢ô |
- Installing process:
- Unload the lamp holder, fix the base on the wall with dilatant screws;
- Connect the power source according to connection-wire figure ;
- Fix the lamp on the base, and then electrify it.

NOTE:
- Avoid installing it where sun shine or air stream and temperature alter obviously;
- Avoid touching the detection window with sharp things or coarse pollutant.
- For maximum coverage of area the unit should be mounted 2.5m above the ground . If mounting the unit at 2.5m is impractical, the unit may be mounted either or lower however the effective larger area way varies from the specifications.
- The unit works by sensing a moving heat source in the larger area. The sensor should be adjusted to point slightly downward for best operation. The light bulbs should also be adjusted to point slightly downward for best operation. NOTE: be sure the light heads should not be adjusted to shine directly on the PIR or close to sensor, otherwise the heat from the bulb will effect the sensor;
- If you are unfamiliar with electrical wire it is recommended you secure the services of a qualified electrician who can insure the installation meets national and local electrical codes.
- Avoid exposing it in a rainy directly location. ;
TEST:
After installing, turn TIME-knob (2) to minimum anticlockwise before electrifying it; turn LUX-knob to maximum (3) anticlockwise.
- The lamp should be on after electrifying it, make it sense 30s later after it died out.
- If all are normal, turn the delay-time knob to set the lighting time according to your desire, LUX-knob (3) to set ambient light and SENS-knob (1) to set detection distance.
|