SL090 Infrared Motion Sensor Switch
Instruction
Welcome to using the
SL09 infrared automatic switch!
The product is a new energy-saving switch; it adopts integrated circuit, high sensitivity detector and controlling silicon technology etc. It gathers automatism, convenience, safety, energy saving and practicality. The wide detection field is made up of the up and down, left and right service fields .It works by receiving human infrared rays. It can start the controlled load at once when one enters the detection field. It can identify day and night automatically. It can fit all kind of palace lamp.
Specifications:
Power source: 100V/AC~130V/ACRated load: 100W(max)
220V/AV~240V/AC
Detection distance: 8m(max) (<24¡æ)
Power frequency: 50~60HzDetection Range:120¡ã
Ambient-light: <10LUX~2000LUX( adjustable)Working temperature:-20¡æ~40¡æ
Working humidity: <93%RHDetection motion speed:0.6~1.5m/s
Power consumption:0.45W (static 0.1W)
Time-delay: min: 5sec
Max:7Min¡À2Min
Functions:

|
Correct moving orientation |
|
Incorrect moving orientation |
|
diagram (¢ñ) |
|
- Detection field: The wide detection field is made up of the up and down, left and right service field (see the following diagram (¢ñ).) But there is the relationship between the sensitivity and orientation of moving in the detection field.
- Can identify day and night: the ambient-light can be adjusted freely when it works. It can work in the daytime and at night when it is adjusted on the ¡°sun¡± position (max); but it can only work in the ambient-light less than 10lux when it is adjusted on the ¡°moon¡± position (min). As for the adjustment pattern, please refer to the testing pattern.
- Time-delay can be added continually: when it received the second induction signal after the first .it will compute time once more on the rest of the first time-delay basic.
- Time-delay adjustment: it can be set freely according to the consumer¡¯s desire. The minimum time is 5sec. The maximum is 7min¡À2min
Installation:
- Switching off the power.
- The spiraling tube is linked on the power and controlling wire.
- Connect the power and the load with the sensor according to the connection-line diagram.
Fix the sensor on the palace lamp. The detection window and the front of the palace lamp are on the same position.
Connection-wire diagram (see the right fig)
Test:
- Turn the light-control knob anti-clockwise on the maximum position (sun). Turn time knob anti-clockwise on the minimum position.
- The controlled load should not work when you switch on the power, after 5~10sec, the load should work. Under the condition of no induction signal. The load should stop working within 5~30sec.
- After the first is out, make it sense after 5~10sec, the load should work and stop working within 5~15sec.
- Turn the ambient-light knob anti-clockwise on the minimum .the inductor load should not work when it works in the ambient-light beyond 10lux. The load should work when you cover the detection window with opaque objects (black cloth etc), under the condition of no induction signals, the load should stop working within 5~15sec.
Notes:
- Electrician or experienced human can install it.
- The unrest objects can¡¯t be regarded as the installation basis-face (with lamp condition)
- In front of the detection window there shouldn¡¯t be hinder or unrest objects effecting detection.
- Avoid installing it near air temperature alteration zones for example: air condition, heater etc.
- Please don¡¯t open the case for your safety if you find the hitch after installation.
SOME PROBLEM AND SOLVED WAY
- The load don¡¯t work£º
a.please check if the connection of the power and the load is correct£»
b.If the load is good£»
c.if the working light correspond to the ambient light¡£
- The sensitivity is poor£º
a.Please check if in front of the detection window there is hinder which effect it to receive signals¡£
b.Please check the ambient temperature;
c.Please check if the signals source is in the detection fields;
d.Please check the installation height;
e.If the moving orientation is right.
- The sensor can¡¯t shut automatically the load:
a.If there are continual signals in the detection fields;
b.If the time delay is set to longest;
c.If the power correspond to the instruction.
d.If the air temperature change near the sensor, for example aircondition or central heating etc.
|